RE: RE: Viper Fan - Technical Info?

From: Bernd D. Ratsch (fasstdak@hotmail.com)
Date: Mon Jun 28 2004 - 01:14:04 EDT


Most likely the circuit used. No failed fans on the Vipers.

- Bernd

-----Original Message-----
From: owner-dakota-truck@bent.twistedbits.net
[mailto:owner-dakota-truck@bent.twistedbits.net] On Behalf Of srp@cox.net
Sent: Sunday, June 27, 2004 9:37 PM
To: dakota-truck@dakota-truck.net
Subject: Re: RE: DML: Viper Fan - Technical Info?

Regardless of what the viper has-- people running 50 amp relays (even the
ones from Mopar for the viper fan) have shown to fail in as little as 6
months time-- why? Most likely the load-- and associated drain on the
battery that people subject their truck to that the Viper will never see
(fan on 99% of the time while towing, big stereos, fog lamps, a ton of low
speed driving, etc.) That load can underpower the relay... try flipping a
light bulb on and off a bunch of times-- eventually it'll pop due to the
high load demand. I've built my Viper wiring kit on a solid foundation,
that is more than 'just enough' in terms of relays/wiring. The fan runs
30-35 amps continuous on low speed, and 50 amp draw on initial turn on.
High speed is near 40 amps continuous. I'd hate to have someone running
their configuration and have a relay fail in AZ in the middle of the
summer...

Sam
www.socaldakota.com
619-274-1292

>
> From: "Bernd D. Ratsch" <fasstdak@hotmail.com>
> Date: 2004/06/27 Sun PM 07:38:57 EDT
> To: <dakota-truck@dakota-truck.net>
> Subject: RE: DML: Viper Fan - Technical Info?
>
>
> Again...and strangely enough, the actual Vipers only run 50 amp relays
> - no need for 75amp units.
>
> - Bernd
>
> -----Original Message-----
> From: owner-dakota-truck@bent.twistedbits.net
> [mailto:owner-dakota-truck@bent.twistedbits.net] On Behalf Of
> srp@cox.net
> Sent: Sunday, June 27, 2004 3:16 PM
> To: dakota-truck@dakota-truck.net
> Subject: Re: DML: Viper Fan - Technical Info?
>
>
>
> The 40 won't be enough... at least over time. My kit which is going
> through durability testing now runs 2- 75 AMP Bosch relays, and 50 amp
> fuse. So far no issues, and nothing but good results.
>
> Sam
> www.socaldakota.com
> 619-274-1292
>



This archive was generated by hypermail 2b29 : Thu Jul 01 2004 - 00:15:18 EDT