RE: heater and defrost fan and control

From: Robert Setree (agm@agm.win.net)
Date: Tue Jan 22 2008 - 14:48:54 EST


Are they interchangeable if I am willing to put spade terminals on the
existhing wires?

-----Original Message-----g
From: owner-dakota-truck@bent.twistedbits.net
[mailto:owner-dakota-truck@bent.twistedbits.net] On Behalf Of Bernd D.
Ratsch
Sent: Monday, January 21, 2008 6:06 PM
To: dakota-truck@dakota-truck.net
Subject: RE: DML: heater and defrost fan and control

Yup...the newer (ceramic) ones don't burn up like the older resistor boards.

- Bernd

-----Original Message-----
From: Robert Setree [mailto:agm@agm.win.net]
Sent: Monday, January 21, 2008 11:26 AM
To: dakota-truck@dakota-truck.net
Subject: RE: DML: heater and defrost fan and control

Good info. My wiring harness had burn up before and I have spade terminals
on my wires plugging into the resistor bank. I can get some use from this.

-----Original Message-----
From: owner-dakota-truck@bent.twistedbits.net
[mailto:owner-dakota-truck@bent.twistedbits.net] On Behalf Of David Gersic
Sent: Sunday, January 20, 2008 8:16 PM
To: dakota-truck@dakota-truck.net
Subject: Re: DML: heater and defrost fan and control

On Sunday 20 January 2008 05:54 pm, Robert Setree wrote:
> No speeds work. I have voltages on some terminals. I will take it
> loose and look at the windings.

http://www.zaccaria-pinball.com/temp/im005442.jpg

The black one on the left is the original I pulled out. I had only high
speed working, so there was at least some of the resistor wire intact, but
the other taps were beyond the open.

The green one on the left is the replacement.

http://www.zaccaria-pinball.com/temp/im005443.jpg

The left two terminals are common. The three on the right have different
resistance readings with a meter, leading to four total fan speeds.



This archive was generated by hypermail 2b29 : Fri Feb 01 2008 - 01:11:51 EST