Fuses, was viper fan wiring

From: Mallett, Donald B (Donald.Mallett@BNSF.com)
Date: Sat Jul 05 2003 - 00:48:53 EDT


One note not touched on with the fuse sizing. That fuses are rated on a
continual amperage. The 100amp blade fuse I picked up at a car audio shop
is rated 100amp continual and rated 200amp for 5 seconds. Before I found out
that the fan pulls 105amps at start-up, I had picked up 2, 50 and 2, 60amps
fuses to try. The 60 is holding just fine. I might try the 50amp just to see
if it holds.

*-------------------------------Y2KOTA-------------------------------*
Don Mallett
Y2K QC 4.7L Auto SLT+
http://www.mallettservices.com/y2kota.html
http://www.dakota-truck.net/profiles/dakota/QwkvWz@DAJFf6/profile.htm
*-------------Straight home & no playing in the puddles!-------------*